68 Life Technologies ™ | Clone Screening Q: A: How should I scale up the clones from 96-well plates to shake flasks? The flowchart (Figure 16) depicts a suggested workflow for the major steps in the clone scale-up and screening procedure following identification of clones to be scaled up from the 96-well plate in primary screen. Clone Screening Q: A: What is the typical glutamine and ammonium profile of monoclonal antibody-expressing CHO-S ® clones? Here are typical glutamine and ammonium profiles (Figures 14 and 15) for a clone in a 14-day productivity assessment in CD FortiCHO ™ Medium + 8 mM glutamine + 1:100 Anti-Clumping Agent with glucose feeding on days 3, 5, and 7 (at 4, 4, and 6 g/L, respectively).